Why does it turn by itself when not running?????....what can I do to stop it....
Johnny Reb
|
|
|
|
Joined: Dec 2016
Posts: 656 Likes: 3
Oil Can Mechanic
|
Oil Can Mechanic
Joined: Dec 2016
Posts: 656 Likes: 3 |
Un-stick the cutout points in your voltage regulator.
|
|
|
|
Joined: May 2008
Posts: 201
Backyard Mechanic
|
OP
Backyard Mechanic
Joined: May 2008
Posts: 201 |
Johnny Reb
|
|
|
|
Joined: Dec 2007
Posts: 4,024 Likes: 99
ChatMaster - 4,000
|
ChatMaster - 4,000
Joined: Dec 2007
Posts: 4,024 Likes: 99 |
I am interested in how you discovered this situation. I did not realize that the generator had enough power to turn over the engine when it was run as an electric motor.
I agree that the cutout points in the regulator are not opening like they should when the output voltage from the generator drops.
Rusty
VCCA #44680
|
|
|
|
Joined: Aug 2006
Posts: 1,774 Likes: 4
ChatMaster - 1,500
|
ChatMaster - 1,500
Joined: Aug 2006
Posts: 1,774 Likes: 4 |
That is what I was wondering, must have had the fan belt off.
Ed
|
|
|
|
Joined: Oct 2009
Posts: 1,294
ChatMaster - 1,000
|
ChatMaster - 1,000
Joined: Oct 2009
Posts: 1,294 |
If interested in a good Deco Remy regulator let me know. I have several. $40.00 plus the ride.
|
|
|
|
Joined: Jan 2002
Posts: 30,701 Likes: 141
ChatMaster - 25,000
|
ChatMaster - 25,000
Joined: Jan 2002
Posts: 30,701 Likes: 141 |
Three different voltage regulators were used in 1952 with the various three generators. The correct regulator must be used depending on the number of the generator.
Gene Schneider
|
|
|
|
Joined: May 2008
Posts: 201
Backyard Mechanic
|
OP
Backyard Mechanic
Joined: May 2008
Posts: 201 |
Yes......The fan belt is new but may have worked loose over the last few days...I still did not know or have ever seen a generator turn by itself.
Johnny Reb
|
|
|
|
Joined: May 2008
Posts: 201
Backyard Mechanic
|
OP
Backyard Mechanic
Joined: May 2008
Posts: 201 |
Ok....let me check it out some more..
Johnny Reb
|
|
|
|
Joined: May 2008
Posts: 201
Backyard Mechanic
|
OP
Backyard Mechanic
Joined: May 2008
Posts: 201 |
Johnny Reb
|
|
|
|
Joined: Nov 2001
Posts: 19,758 Likes: 64
ChatMaster - 15,000
|
ChatMaster - 15,000
Joined: Nov 2001
Posts: 19,758 Likes: 64 |
That reminds me to check the reading on the ammeter when you shut off the engine of a Chevy. Anything toward discharge may be stuck regulator or cut-out points.
How Sweet the roar of a Chevy four!
|
|
|
|
Joined: May 2008
Posts: 201
Backyard Mechanic
|
OP
Backyard Mechanic
Joined: May 2008
Posts: 201 |
TY...Chipper...I will check in the morning....I noticed it all the way over on charge and did not think of that...I thought it was just charging...
Last edited by dwpirkeyjr; 12/17/19 09:48 PM.
Johnny Reb
|
|
|
|
Joined: Sep 2009
Posts: 6,689 Likes: 21
ChatMaster - 6,000
|
ChatMaster - 6,000
Joined: Sep 2009
Posts: 6,689 Likes: 21 |
The generator is a motor. It will turn if enough juice is going to it on wrong posts. Juice and grounded. Are you sure you have it wired correctly? Best, Charlie 
|
|
|
|
Joined: May 2008
Posts: 201
Backyard Mechanic
|
OP
Backyard Mechanic
Joined: May 2008
Posts: 201 |
No, I am not sure... I did not change it but have never checked it either...
Johnny Reb
|
|
|
|
Joined: Dec 2007
Posts: 4,024 Likes: 99
ChatMaster - 4,000
|
ChatMaster - 4,000
Joined: Dec 2007
Posts: 4,024 Likes: 99 |
I assume that you are disconnecting the battery when you are not troubleshooting this. Otherwise you will at a minimum run the battery down or potentially create an electrical fire.
Rusty
VCCA #44680
|
|
|
|
Joined: Sep 2006
Posts: 1,255 Likes: 10
ChatMaster - 1,000
|
ChatMaster - 1,000
Joined: Sep 2006
Posts: 1,255 Likes: 10 |
That used to be one of the shade tree mechanic tests we would use. If it wasn't charging put voltage to the generator. If it spun the problem was probably in the regulator.
|
|
|
|