I need to be on the look out to purchase a new generator cut out (6v of course) for my 1931 this spring and would like a little help on the correct Delco part number that I should be looking for when at the swap meets.
Could someone help with a little direction on part numbers. Thanks!! John Lanning
John Lanning
|
|
|
|
Joined: Mar 2011
Posts: 229
Backyard Mechanic
|
Backyard Mechanic
Joined: Mar 2011
Posts: 229 |
I have a working one available. It has been restored. Contact me in My Stuff.
|
|
|
|
Joined: Feb 2006
Posts: 2,262 Likes: 6
ChatMaster - 2,000
|
ChatMaster - 2,000
Joined: Feb 2006
Posts: 2,262 Likes: 6 |
The original part number was 828391, but there are several later part numbers which will also work on your car and are shown as replacement or service parts for your car in later catalogs. They do show up on ebay periodically. Hope that helps.
All the Best, Chip
"It's wise to choose a SIX"
|
|
|
|
Joined: Feb 2007
Posts: 860
ChatMaster - 750
|
ChatMaster - 750
Joined: Feb 2007
Posts: 860 |
My old parts book shows Generator Circuit Breaker (cut out) for 1929-39 all exc. HA,HB,JA,JB,COE as part number 827843. (grp 2.319)
hoppy
Last edited by n2chev; 04/02/13 12:28 PM.
"Four-Doors-Forever"
|
|
|
|
Joined: Dec 2001
Posts: 10,379 Likes: 1
Technical Advisor ChatMaster - 10,000
|
Technical Advisor ChatMaster - 10,000
Joined: Dec 2001
Posts: 10,379 Likes: 1 |
Do you have the old cut-out? If so, I can convert it to solid state.
If you don't have a core I can furnish it and it will be converted to solid state.
RAY Chevradioman http://www.vccacolumbiariverregion.org/1925 Superior K Roadster 1928 Convertible, Sport, Cabriolet 1933 Eagle, Coupe 1941 Master Deluxe 5-Passenger Coupe 1950 Styleline Deluxe 4-Door Sedan 1950 Styleline Deluxe Convertible 2002 Pontiac, Montana, Passenger Van 2014 Impala, 4-Door Sedan, White Diamond, LTZ 2017 Silverado, Double Cab, Z71, 4X4, White, Standard Bed, LTZ If you need a shoulder to cry on, pull off to the side of the road. Death is the number 1 killer in the world.
|
|
|
|
Joined: Dec 2001
Posts: 168 Likes: 1
Shade Tree Mechanic
|
OP
Shade Tree Mechanic
Joined: Dec 2001
Posts: 168 Likes: 1 |
Sorry folks but have been away for a while....thanks for the information on the cut out numbers and options. I was able to find another relay that works well but may consider a diode conversion as another replacment for a backup. I appreciated your advice! John
John Lanning
|
|
|
|
Joined: Nov 2008
Posts: 322
Backyard Mechanic
|
Backyard Mechanic
Joined: Nov 2008
Posts: 322 |
I'd put in a diode in series with the cutout as extra insurance. If your cutout sticks it can fry your generator, wreck your battery, and start a fire.
|
|
|
|
Joined: Mar 2004
Posts: 129
Shade Tree Mechanic
|
Shade Tree Mechanic
Joined: Mar 2004
Posts: 129 |
this sounds like a great idea. as a non electronic hammer mechanic, I have no idea of the specifics of this. please get specific and simple for me. thanks for the patience.
they don't make em like they usedta
|
|
|
|
Joined: Mar 2012
Posts: 151
Shade Tree Mechanic
|
Shade Tree Mechanic
Joined: Mar 2012
Posts: 151 |
I had the Filling station do my cutout to modern specs w/diode on my '32.It uses the same original cutout housing but internally it has a diode from an alternator.Just be careful that your generator does'nt generate more than 10 amps or so or it will melt the solder on the diode and ruin it.I found this out the hard way.Having melted three before we figured it out.The Filling station and their outsource were very patient and helpful in determining the problem.The old original cutout fried my gen.and ruined my battery.
kerry j camp
|
|
|
|
Joined: Nov 2008
Posts: 322
Backyard Mechanic
|
Backyard Mechanic
Joined: Nov 2008
Posts: 322 |
Diodes generate heat and need a heat sink to dissipate the heat.
|
|
|
|
|