VISITORS: You are welcome to read our forums. If you want to participate FREE then you need to register. Join the VCCA and get access to the member-only features of the forum, including the ability to attach/upload photos. You'll also receive our monthly magazine "Generator & Distributor". Yearly membership as low as $25!

VCCA MEMBERS: Already a member? Great! Info to access the members-only area.

Topic Options
Rate This Topic
#369465 - 06/01/16 09:19 PM Generator
greencorn Offline

Backyard Mechanic

Registered: 07/14/03
Posts: 488
Loc: vallejo, ca
Will the generator be damaged if the battery becomes disconnected while the engine is running (I have a fuse in the circuit, will it blow the fuse first)?

ron
_________________________
ron

Top
Vintage Auto Garage - 12 Volt
#369478 - 06/02/16 03:06 AM Re: Generator [Re: greencorn]
Uncle Ed Offline

1000

Registered: 08/30/06
Posts: 1324
Loc: Iowa
If I remember correctly, years ago,
I disconnected the battery with the engine running and it did not damage the generator and the car kept running on the output from the generator. I don't think it will hurt the generator.
_________________________
Ed

Top
#369494 - 06/02/16 12:09 PM Re: Generator [Re: Uncle Ed]
chevy1937 Offline

pumpjockey

Registered: 10/30/09
Posts: 920
Loc: Hubbard,Ohio
I agree. Did that more than once.

Top
#369496 - 06/02/16 12:44 PM Re: Generator [Re: chevy1937]
tonyw Offline




Registered: 05/23/02
Posts: 4174
Loc: Goulburn Australia
I have never damaged a generator by disconnecting whilst running, dont know of any alternators either for that matter. Admittedly I dont make a practice of it either just in case I get caught.
Tony
_________________________
1938 1/2 ton Hope to drive it before I retire

Top
#369501 - 06/02/16 02:53 PM Re: Generator [Re: tonyw]
Junkyard Dog Offline




Registered: 11/23/01
Posts: 28629
Loc: Eagle Point, Oregon
I strongly recommend against it!

laugh wink beer2
_________________________
The Mangy Old Mutt

"If It's Not Junk.....It's Not Treasure!"

Top
#369511 - 06/02/16 06:17 PM Re: Generator [Re: Junkyard Dog]
greencorn Offline

Backyard Mechanic

Registered: 07/14/03
Posts: 488
Loc: vallejo, ca
I posted this question on another website and the majority response was that it will do no harm: So which is it, can't be both, either it definitley will damage the generator or it will not. Guess I'll just try it out and find out for myself. I thought someone would know for sure.
_________________________
ron

Top
#369591 - 06/03/16 06:22 PM Re: Generator [Re: greencorn]
Junkyard Dog Offline




Registered: 11/23/01
Posts: 28629
Loc: Eagle Point, Oregon
I had the ground cable get disconnected from the battery once and because the battery was no longer in the circuit to act as a ballast, the generator put out excessive voltage and fried every light bulb in the vehicle that was on at the time. Anyway, go ahead and try disconnecting the battery while the car is running if you feel that you must. Don't know why you would want to do it though.

laugh wink beer2
_________________________
The Mangy Old Mutt

"If It's Not Junk.....It's Not Treasure!"

Top
#369597 - 06/03/16 08:39 PM Re: Generator [Re: Junkyard Dog]
greencorn Offline

Backyard Mechanic

Registered: 07/14/03
Posts: 488
Loc: vallejo, ca
Thanks Dog. The generator (old North East) is in an old FWD truck and not connected to any electrical except the starter. The generator has a fuse on top and was wondering what would happen if the fuse blows or becomes disconnected from the battery. I'd never find another one so didn't want to worry about burning mine up in case something became unconnected.
_________________________
ron

Top
#369604 - 06/03/16 10:50 PM Re: Generator [Re: greencorn]
Chipper Offline




Registered: 11/22/01
Posts: 16632
Loc: The Great State of TEXAS
Generators that regulate output with a properly wired and adjusted third brush are not as likely to "run away" and destroy themselves. With a voltage regulator that might not be the case.
_________________________
How Sweet the roar of a Chevy four!

Top
#369607 - 06/03/16 11:32 PM Re: Generator [Re: Chipper]
Junkyard Dog Offline




Registered: 11/23/01
Posts: 28629
Loc: Eagle Point, Oregon
Generators with a third brush will usually go to maximum voltage if the battery is not in the circuit to act as a ballast.

laugh wink beer2
_________________________
The Mangy Old Mutt

"If It's Not Junk.....It's Not Treasure!"

Top
#369611 - 06/04/16 12:12 AM Re: Generator [Re: Junkyard Dog]
Chipper Offline




Registered: 11/22/01
Posts: 16632
Loc: The Great State of TEXAS
That is what I was trying to get people to understand. The 3rd brush limits the amount of power to the field coils and therefore output. Output = heat that can overheat the generator. That is particularly the case for the early non-ventilated versions.
_________________________
How Sweet the roar of a Chevy four!

Top


Moderator:  AntiqueMechanic, d2d2 
Your Status
Please login to post or reply.* * *
Send My Password
Who's Online
1 Chat Members (Peter_Gariepy), 0 Lookie Loo's and 26 Spiders or Bots online.
Key: Admin, Global Mod, Mod
Today's Birthdays
32confederate
Helpful Links
Forum Registration
New User Forum
Members Only Forum
Reset Your Password
Kill Your Cookies

VCCA Home
Join the VCCA
Member Photos
My 31' Chevy Show
What is missing?
31' headlight reflectors re-silvered at home
1936 Roadster - S. Africa
Chevy on the Levee
'37 Seat
Forum Stats
15086 Chat Users
79 Forums
50178 Topics
366686 Posts

Max Online: 304 @ 06/18/16 10:00 AM

 

Notice: Any comments posted herein do not necessarily reflect the official position of the VCCA.